Re: WC 5325 error 121-312 urgent !

$
0
0

121-312 IC Card Auditron Config Fail 02


Control Fail. When the power is turned On, an error occurred due to the combination of setting
that is not permitted.


• EP-related products other than IC Card Gate is connected (set), or IC Card Gate and
other EP-related products are connected (set) together.


• [Authentication/Counting Management] > [Authentication/Counting Operation] is set to
[External Authentication/Counting].


Procedure
Actions to be taken are as follows:
1. Activate without connecting EP-related product, and set [Authentication/Counting Management]
> [Authentication/Counting Operation] to other than [External Authentication/
Counting].


2. Attach the optional external authentication kit for IC card, and set the single connection of
IC Card Gate of EP-related product.